st jude pacemaker mri compatibility
Rate-Adaptive Pacing may be inappropriate for patients who experience angina or other symptoms of myocardial dysfunction at higher sensor-driven rates. Abbotts MRI-Ready High Voltage Device Setup for Gallant and Entrant ICD and CRT-Ds (11:45). Brief Summary:Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use. St. Jude Medical. Scan Regions. It requires a special lead system, so the generator cannot be simply replaced and connected to in situ intracardiac leads. Premature ventricular contractions have been observed, but they have been clinically insignificant. 2,3. The Assurity MRI pacemaker provides an option that can help patients receive a timely diagnosis so that they can get the care they need, when they need it. We recommend that you download and review the most current version any time a patient with an Abbott product needs an MRI. Read our privacy policy to learn more. Rate-Modulated Pacing is indicated for patients with chronotropic incompetence, and for those who would benefit from increased stimulation rates concurrent with physical activity. Patients are supervised by a cardiologist or pacemaker nurse through the procedure. ** ISO standard settings: VVIR, 60bpm, 2.5V @0.4 ms, 600 , 100% pacing
Feb 2001 - Dec 201716 years 11 months. Edwards . The information provided here is not intended to provide information to patients and the general public. The Merlin PCS Programmer will print to the default printer (internal printer, external printer or PDF). "This new technology allows patients who have heart failure that is challenging to manage to receive more effective therapy and still be able to get an MRI for other medical conditions if needed," Philip Adamson, M.D., medical director of global research and development at St. Jude, said in the statement. Each lead needs to be checked for MRI compatibility and individual scan parameters. Cardiac Pacemakers, Implantable Cardioverter Defibrillators (ICDs), and Cardiac Monitors More. 348. Copyright 2023. Please refer to the MRI Technical Guide: ImageReady MR Conditional Pacing System as the system is designated as MR Conditional in accordance with specific conditions. Abbott and St. Jude Medical, Cardiac Pacemaker List of MR Conditional Versions Abbott and St. Jude Medical, Inc., www.sjm.com/mriready NOTE: Certain devices are MR Conditional at 1.5 T and others are, Abbott and St. Jude Medical, Cardiac PacemakerList of MR Conditional VersionsAbbott and St. Jude Medical, Inc., www.sjm.com/mriready NOTE: Certain devices are MR Conditional at 1.5 T and others are MR, Accent MRI and Accent ST MRI Cardiac Pacemaker Systems,Models PM1224,PM2224, PM1226, PM2226, PM1124 PM2124,St. 2 06/12/2018 St Jude Medical Inc. Article Text. SKU: CD3357-40Q Weight: 3.00 LBS Availability: 4-5 Business days Shipping: Calculated at checkout : Quantity: Share. Accessed January 11, 2020. With all medical procedures there are risks associated. Rev B. Romeyer-Bouchard, C., Da Costa, A., Dauphinot, V., Messier, M., Bisch, L., Samuel, B, Isaaz, K. (2010). The MRI conditional labelling for the Nanostim leadless pacemaker is expected shortly in the EU. Proper patient monitoring must be provided during the MRI scan. The MRI pulse sequences are determined by the radiologist and the physicist. Accessed December 18, 2020. St Jude Medical Inc. Z-0035-2018 - PM1226 ACCENT ST MRI SR RF and PM2222 ACCENT ST These low voltage (LV) devices are implantable pacemaker pulse generators, intended to be permanently implanted in the body, that have a power supply a. "We are in constant communication with regulatory agencies and competent authorities worldwide which allows us to implement global recalls or in-country communication quickly and . The MRI. Jude Medical, Inc., www.sjm.com/mriready. Sylmar CA. "All the exams take place on a 1.5-tesla magnet, and the specific absorption rate is limited to 1.5 W/kg for a maximum of 30 minutes," according to Joel P. Felmlee, Ph.D., a radiation physicist at Mayo Clinic in Minnesota. Labeling does not contain MRI Safety Information: Human Cell/Tissue Product: false: Device Kit: false: Device Combination . Cardiac MRI is excluded because of potential overheating of the new lead system (second-generation devices currently available in Europe use a lead system that is compatible with cardiac MRI). If a device is not shown in the list, it is not MR Conditional. JUDE MEDICAL INC. St. Jude Medical Research Report: Competitive Product Review: Wireless Pacemakers. Mayo Clinic is a not-for-profit organization. The Assurity MRI Cardiac Pacemaker System (Models PM1272, PM2272; St. Jude Medical, Inc., St. Paul, MN) has been designed and tested for performance of an MRI examination using a 1.5-T (Tesla) field-s. More . ST. JUDE MEDICAL, Accent, Accent MRI, Assurity MRI, Durata, Ellipse, Endurity, Endurity MRI, Fortify Assura, IsoFlex, Optisure, . Power-on resetting (POR) and magnet mode pacing have been observed in some patients and seem to be device specific. MRI should not be performed if there is evidence of generator or lead malfunction. Copyright 2023 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All rights reserved. This site uses cookies. You can search by product, model number, category or family. An appropriate Maximum Sensor Rate should be selected based on assessment of the highest stimulation rate tolerated by the patient. Unless otherwise specified, all product names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. Adverse Events: Potential complications associated with the use of the Aveir Leadless Pacemaker system are the same as with the use of single chamber pacemakers with active fixation pacing leads including, but not limited to: Cardiac perforation, Cardiac tamponade, Pericardial effusion, Pericarditis, Valve damage and/or regurgitation, Heart failure, Pneumothorax/hemothorax, Cardiac arrhythmias, Diaphragmatic/phrenic nerve stimulation / extra-cardiac stimulation, Palpitations, Hypotension, Syncope, Cerebrovascular accident, Infection, Hypersensitivity reaction to device materials, medications, or direct toxic effect of contrast media on kidney function, Pacemaker syndrome, Inability to interrogate or program the LP due to programmer or LP malfunction, Intermittent or complete loss of pacing and/or sensing due to dislodgement or mechanical malfunction of the LP (non-battery related), Loss of capture or sensing due to embolization or fibrotic tissue response at the electrode, Increased capture threshold, Inappropriate sensor response, Interruption of desired LP function due to electrical interference, either electromyogenic or electromagnetic, Battery malfunction/ premature battery depletion, Device-related complications (Premature deployment, Device dislodgement/embolization of foreign material, Helix distortion), Death. Antigua and Barbuda CapSure Sense MRI SureScan Models 4074, 4574 Presented at the XV International Symposium on Progress in Clinical Pacing, Rome, Italy. 343. Web page addresses and e-mail addresses turn into links automatically. Jude Medical, Inc., www.sjm.com/mriready, Adapta Cardiac PacemakerMedtronic, Inc., www.medtronic.com, ADVANTIO MRI PacemakerCardiac PacemakerBoston Scientific, www.bostonscientific.com, Advisa DR MRI SureScan Pacing SystemAdvisa DR MRI SureScan A2DR01 Digital Dual Chamber Pacemaker and SureScan LeadsCardiac PacemakerMedtronic, Inc., www.Medtronic.com/MRI, Assurity MRI Cardiac Pacemaker SystemModels PM1272, PM2272St. After recovery of battery voltage, devices typically reset to the manufacturer's nominal settings. %%EOF
EDORA 8 HF-T/HF-T QP: 1.5 FBS in combination with Solia S 45 lead. 36 J. MR Conditional The pulse generator, along with compatible, commercially available leads, constitutes the implantable portion of the ICD and CRT-D systems. The Aveir LPs predicate device has chronic retrieval success rate >80% with helix fixation through 7 years regardless of implant duration
Are you a healthcare professional? 339. The MRI parameter settings are selected at the physician's discretion. Safety Info ID#. Information about the lead (s) and battery function is continuously recorded. MRI-Ready Systems Manual MRI Procedure Information for the St. Jude Medical MR Conditional System [PDF 1.09 MB] (EN) Order a paper copy PM2224 Accent MRIPacemaker_O_US, LPA1200M/46 CM, LPA1200M/52 CM, LPA1200M/58 CM, 1944/46 IsoFlexOptim Leads Assy, 1944/52 IsoFlexOptim Leads Assy, 1948/52 I More Following is some high-level information about preparing for and administering an MRI with patients with a leadless pacemaker, traditional pacemaker, ICD, CRT-D or CRT-P. Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. On February 29, 2012. the pacemaker unit at the hospital checked the pacemaker and I was told that the lead has to replaced because the ba read more
Paul, M, Endurity Cardiac Pacemaker SystemModels PM1162, PM2162St. Dual-chamber implantable pacemaker, rate-responsive Dual-chamber implantable pacemaker, rate-responsive Dual-chamber implantable pacemaker, rate-responsive Dual-chamber . St. Jude medical CD3357-40Q UNIFY ASSURA Cardiac Resynchronization Therapy (CRT) Defibrillator. 100173657, 600135977, 100002504, 100055011, 100054876 More. The subsequent launch of similar MRI-compatible pacemakers by competitors Boston Scientific and Medtronic undercut St. Jude's bottom line in its cardiac rhythm segment. Download the MRI Ready Systems Manual or MRI Ready Leadless System Manual to check the MRI scan parameter tables for the applicable scan and identify the settings for RF Transmit Conditions and scan regions. Precautions
This content does not have an Arabic version. Use this database for coronary intervention, peripheral intervention and valve repair products. W3SR01. MD+DI Online is part of the Informa Markets Division of Informa PLC. The following, in addition to the above, are potential complications associated with the use of rate-modulated pacing systems: inappropriate, rapid pacing rates due to sensor failure or to the detection of signals other than patient activity, loss of activity-response due to sensor failure, palpitations with high-rate pacing. Endurity Pacemaker Designed for ease of implant and a smaller incision and pocket size, the Endurity pacemaker can help reduce RV pacing and heart-failure hospitalization with beat-by-beat ventricular support. Prior to use, reference the Instructions for Use, inside the product carton (when available) or online for more detailed information on Indications, Contraindications, Warnings, Precautions and Adverse Events. Ventricular Pacing is indicated for patients with significant bradycardia and normal sinus rhythm with only rare episodes of A-V block or sinus arrest, chronic atrial fibrillation, severe physical disability. The St. Jude Medical Merlin Patient Care System (PCS) with software model 3330 version 24.0.1 (or greater), a Merlin Antenna (for devices with RF communication), and a telemetry wand constitute the external portion of the ICD and CRT-D systems. Aveir TM Link Module Instructions for Use. At routine clinic visits this information is retrieved from the pacemaker to guide decisions about your ongoing management. Our manuals contain the latest instructions and information for cardiac physicians, radiologists and MR technologists. Boston Scientific offers patients with a wide range of implantable pacing and defibrillation systems designed for the MRI environment. Your pacemaker is continuously monitoring its own function and analysing your heart rhythm. Chronotropic competence is defined by the Model of the Cardiac Chronotropic Response to Exercise. Single-Chamber Atrial Pacing is relatively contraindicated in patients who have demonstrated compromise of AV conduction. The current guidelines from the American Heart Association and the Food and Drug Administration (FDA), however, do not support MRI in patients with pacemakers, nor do any of the device manufacturers' guidelines (except for new MRI-conditional devices). Pulse oximetry and ECG are monitored. An estimated 75 percent of patients who currently have an implantable cardiac electronic device will need magnetic resonance imaging (MRI) during their lifetimes. AF Suppression stimulation is not recommended in patients who cannot tolerate high atrial-rate stimulation. However, it continues not to reimburse for MRIs performed in patients with other pacemaker systems.
The Azure pacemaker is equipped with BlueSync technology and is compatible with MyCareLink Heart mobile app the latest innovation from Medtronic in remote monitoring. Registered in England and Wales. 3. The medical device ASSURITY MRI PM1272 is realized by ST. JUDE MEDICAL INC. Trade name: ASSURITY MRI PM1272: Product Code: PM1272: Manufacturer of the medical device: ST. JUDE MEDICAL INC. Category Name: SINGLE-CHAMBER IMPLANTABLE PACEMAKERS WITH RATE MODULATION SENSOR (SR) Category Code: J01010102: Sign repertoire: Registered: Group of similar . ***Among pacemakers < 15cc in total volume; as of February 1, 2017. The company also. This data is stored in your pacemakers memory. I might be wrong about this, but I think you cannot sell a device as MRI compatible in the U.S. without FDA approval. This webpage is a global search tool of Medtronic, MR-conditional implantable cardiac devices, including pacemakers, ICDs, CRTs, and ICMs. These devices are considered MR Unsafe. Indications: The Aveir Leadless Pacemaker system is indicated for patients with significant bradycardia and normal sinus rhythm with rare episodes of A-V block or sinus arrest, chronic atrial fibrillation and severe physical disability. Most pacemakers made since 2000 are MRI-conditional, meaning they are safe for magnetic resonance imaging. All rights reserved. THE List. Lead model has not been predictive of abnormal pacing function during MRI studies, nor has region of the body scanned. Chronic Retrievability with a Leadless Pacemaker: A Worldwide Nanostim Experience out of 7y. Pacemakers are common implantable medical devices that use mild electric pulses to speed up a heart beat that is too slow. Indications: Implantation is indicated in one or more of the following permanent conditions: syncope, presyncope, fatigue, disorientation due to arrhythmia/bradycardia or any combination of those symptoms. An appropriate Maximum Sensor Rate should be selected based on assessment of the highest stimulation rate tolerated by the patient. -St. Jude Medical Corporate Award: Hendrickson Technical Achievement Award Winner (2007): Page 5 of St. Jude Medical 2007 annual report at http . Manufacturer Address. This includes continuous monitoring of the patient's hemodynamic function. The CapSureFix Novus MRI SureScan Model 5076 was the second pacing lead to be approved for use in the MRI environment. CD1411-36C. It is required to program the device to MRI Settings as part of the MRI scan workflow. This site is Exclusively Sponsored by BRACCO, Assurity MRI Cardiac Pacemaker System, St. Jude Medical, (Models PM1272, PM2272; St. Jude Medical, Inc., St. Paul, MN) has been designed and tested for performance of an MRI examination using a 1.5-T (Tesla) field-s. Jude Medical, Inc., www.sjm.com/mriready, Endurity MRI Cardiac Pacemaker SystemModels PM1172, PM2172St. Ellipse Implantable Cardioverter Defibrillator (ICD) System, St. Jude Medical. hbbd``b`~ $ R $Av@Bd.LBb``J No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company. St. Jude Medicalhas landed the CE Mark for MRI compatibility for its Quadra Allure MP cardiac resynchronization therapy pacemaker. This site is Exclusively Sponsored by BRACCO, Endurity Cardiac Pacemaker System, St. Jude Medical, (Models PM1162, PM2162; St. Jude Medical, Inc., St. Paul, MN) been designed and tested for performance of an MRI examination using a 1.5-T (Tesla) field-st. Advancements in pacemaker technology have introduced smaller devices, physician-preferred shapes, MR Conditional systems, remote monitoring and increased device longevity. Mayo Clinic Helping to Make 3D 'X-Ray Vision' a Reality, EU, UK Reach New Post-Brexit Trade Deal in Northern Ireland, Elizabeth Holmes Uses Birth of Second Child to Seek Prison Delay, ACC.23: Cardiovascular Sector Makes Some Noise, Getinge Faces CE Mark Suspension for Life Support Systems, New Project Explores Next-Gen AI Interaction with Radiologists, Supercapacitor Patch Could Solve Power Problem for Wearables, Allowed HTML tags: . Download the MRI Ready Systems Manual or MRI Ready Leadless System Manual for additional details about patient monitoring. A complete SureScan single chamber (leadless) pacemaker system includes the following components: A SureScan leadless pacemaker device. The Quadra Allure MP CRT-P with MRI labeling is also compatible with St. Jude's SyncAV CRT software, which automatically adjusts pacing based on real-time changes in a patient's cardiac condition. Abbott (formally known as "St. Jude Medical") is recalling a subset of Assurity and Endurity pacemakers built using specific manufacturing equipment, that were then distributed from April. Immediately following the MRI procedure, follow the instructions in the MRI Ready Systems Manual or MRI Ready Leadless System Manual to revert to the permanently programmed settings. Search for arrhythmia, heart failure and structural heart IFUs. Dual-Chamber Pacing is indicated for those patients exhibiting: sick sinus syndrome, chronic, symptomatic second- and third-degree AV block, recurrent Adams-Stokes syndrome, symptomatic bilateral bundle branch block when tachyarrhythmia and other causes have been ruled out. ProMRI System Technical Manual. Boston Scientific +3.3%: 4. Endurity Cardiac Pacemaker System, St. Jude Medical. Hi! If needed, perform capture and sense and lead impedance tests. Azure MRI SureScan. The medical device ASSURITY MRI PM2272 is realized by ST. JUDE MEDICAL INC. Della stessa categoria di dispositivi medici: ENDURITY MRI PM2172 - PM2172 ENDURITY PM2162 - PM2162 KORA 250 DR - TPM010C ENDURITY PM2152 - PM2152 ENITRA 6 DR - 407153 ENITRA 6 DR-T - 407150 ENTICOS 4 DR - 407155 Legenda X3SR01. FDA has approved the Quadra Allure and the SyncAV CRT, and the company said it is working toward FDA approval of MR-conditional labeling for the devices. Download the MRI Ready Systems Manual or MRI Ready Leadless System Manual for details about checking the MRI Settings status with and without the MRI Activator handheld device. The availability of single-chamber PPM can significantly impact economic concerns related to MRI compatibility, allowing its use even in permanent atrial fibrillation patients who do not need a. St Jude Medical Inc., 15900 Valley View Ct, Sylmar CA 91342-3577. For Cardiac Physicians 1) Confirm MRI readiness Prior to use, reference the Instructions for Use, inside the product carton (when available) or online for more detailed information on Indications, Contraindications, Warnings, Precautions and Adverse Events. Rx Only Brief Summary: Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use. Refer to the manuals for CardioMEMS HF System or MR Conditional ICMs for details about MRIs with those devices. Select an MRI Device. Atrial Pacing is indicated for patients with sinus node dysfunction and normal AV and intraventricular conduction systems. Please Enter the Pop Up text to be displayed in Pop Up here. Your pacemaker is designed to work properly around most appliances and tools. The lead systems are implanted using either transvenous or transthoracic techniques. It is intended to assist healthcare professionals in determining if an implanted system is MR Conditional. Accent MRI and Accent ST MRI Cardiac Pacemaker Systems, Models PM1224,PM2224, PM1226, PM2226, PM1124 PM2124, St. Jude Medical, Inc., www.sjm.com/mriready Select the country where the product was sold: Anguilla. Shutterstock You can have an MRI with a pacemaker, as almost all pacemakers are now considered safe for magnetic resonance imaging. Informa Markets, a trading division of Informa PLC. Download the MRI Ready Systems Manual or MRI Ready Leadless System Manual for details on default settings and how to save modified settings for scanning. MRI Compatibility - Pacemaker Supported by working group of pacing and electrophysiology of the French Society of Cardiology Legal notice Privacy policy Contact ABBOTT Pacemaker Pacemaker SEARCH / FILTERING Accent MRI - PM1124, PM1224, PM2124, PM2224 Field strength 1,5 T with exclusion Exclusion zone Thorax Specific conditions Recent studies have suggested that MRI can be done safely in many patients with standard cardiac pacemakers. Use is contraindicated in patients with an implanted vena cava filter or mechanical tricuspid valve because of interference between these devices and the delivery system during implantation. All SJM heart valves and annuloplasty rings are MRI safe (3- Tesla or less). Confirm implant locations and scan requirements for the patient's system. "The Accent MRI pacemaker system meets important clinical needs without compromise by offering superior pacing technology in addition to full MRI-compatible scanning capabilities with no anatomical zone or MRI power restrictions," said Eric S. Fain, M.D., president of the St. Jude Medical Cardiac Rhythm Management Division. Confirm the MR Conditional components and location of the system. Illustrations are artist's representations only and should not be considered as engineering drawings or photographs. The Mayo Clinic Department of Radiology has been providing this service to patients in need of MRI regardless of reimbursement issues. Download latest version here THE List. The association of the use of the ventricular intrinsic preference (VIP) feature with heart failure hospitalization in pacemaker patients.
4. I had a ST JUDE MEDICAL pacemaker implanrted in October 2011. endstream
endobj
2699 0 obj
<. Individual manufacturer allow you to do this and so we have centralised the direct links here: St. Jude bags CE mark for MRI-compatible pacemaker | Fierce Biotech Fierce Pharma Fierce Biotech Fierce Healthcare Fierce Life Sciences Events Research Biotech Medtech CRO Special Reports. Safety Topic / Subject. EDORA 8 pacemaker associated to MRI compatible BIOTRONIK leads. Select a Country. MRI in selected patients with ICDs is currently under investigation. The lead's body has a co-axial design and uses MP35N coils and an Optim outer Dual-Chamber Pacing, though not contraindicated for patients with chronic atrial flutter, chronic atrial fibrillation, or silent atria, may provide no benefit beyond that of single-chamber pacing in such patients. [prod, crx3, samplecontent, publish, crx3tar], https://vascular.abbott.com/,https://mri.merlin.net/,https://www.thelancet.com/,https://www.ahajournals.org/,https://www.onlinejacc.org/,https://jamanetwork.com/,https://www.sciencedirect.com/,https://onlinelibrary.wiley.com/,https://www.cms.gov/,https://www.novitas-solutions.com/,https://event.on24.com/,https://dx.doi.org/,https://www.myloopaccount.com/,https://www.invasivecardiology.com/,https://manuals.sjm.com/,https://www.cardiovascular.abbott, https://dx.doi.org/10.1093/eurheartj/ehp421, Aveir VR Leadless Pacemaker and Delivery Catheter IFU. The Amplia MRI CRT-D SureScan Model DTMB1D4/DTMB1D1 and Amplia MRI Quad CRT-D SureScan Model DTMB1QQ/DTMB1Q1, hereafter referred to collectively as the Amplia MRI CRT-D device, is MR Conditional and, as such is designed to allow patients to be safely scanned by an MRI machine when used according to the specified MRI conditions for use. (Funded by St. Jud CAUTION: These products are intended for use by or under the direction of a physician. Confirm that no adverse conditions to MR scanning are present. Crossley GH, Boyle A, Vitense H, Chang Y, & Mead RH. Sphera MRI SureScan. When programmed to On, the MRI SureScan feature . European Heart Journal, 31(2), 203-210. Lines and paragraphs break automatically. Shellock R & D Services, Inc. email: Frank.ShellockREMOVE@MRIsafety.com. Medtronic +3.6%: 2. W1SR01. One St. Jude Medical Dr., St. Paul, MN 55117 USA, Tel: 1 651 756 2000 SJM.com St. Jude Medical is now Abbott.
The Centers for Medicare and Medicaid Services has approved reimbursement for MRI in patients with the new MRI-conditional pacing system. Patients are supervised by a cardiologist or pacemaker nurse through the procedure. The following pages are intended for medical professionals and provide information on the proper use of products (medical devices, etc.) Article Text. Manufacturer Parent Company (2017) Abbott Laboratories. New pacing systems have recently been specifically designed by the major companies for safe use in the MRI environment (EnRhythm, Advisa, and Revo MRI SureScan pacemakers and CapSureFix MRI.
EnRhythm MRI SureScan Pacing System, Medtronic, Inc. St. Jude Medicalhas landed the CE Mark for MRI compatibility for its Quadra Allure MP cardiac resynchronization therapy pacemaker. Use this database for arrhythmia, heart failure and structural heart products. ST. JUDE MEDICAL, INC. FDA.report . Faulknier, B., & Richards, M. (2012, December). As with any percutaneous catheterization procedure, potential complications include, but are not limited to: Vascular access complications (such as perforation, dissection, puncture, groin pain), Bleeding or hematoma, Thrombus formation, Thromboembolism, Air embolism, Local and systemic infection, Peripheral nerve damage, General surgery risks and complications from comorbidities (such as hypotension, dyspnea, respiratory failure, syncope, pneumonia, hypertension, cardiac failure, reaction to sedation, renal failure, anemia, and death). Rate-Modulated Pacing is indicated for patients with chronotropic incompetence, and for those who would benefit from increased stimulation rates concurrent with physical activity. Biotronik. AF Suppression stimulation is not recommended in patients who cannot tolerate high atrial-rate stimulation. Single-Chamber Atrial Pacing is relatively contraindicated in patients who have demonstrated compromise of AV conduction. If Azure detects changes in your heart, it wirelessly and securely transfers your heart device information to your clinic. THE List. The Endurity Cardiac Pacemaker System (Models PM1162, PM2162; St. Jude Medical, Inc., St. Paul, MN) been designed and tested for performance of an MRI examination using a 1.5-T (Tesla) field-st. LSP112V Aveir VR_Pacer_IDEMRI_US, LSL02, FG, Aveir Link Module,US, IDE, 3650 Merlin PCS, US,with 3330 v6.6.1 SW, 5 LEAD ECG YOKE LABELMODELS 3625, 5 LEAD More. The lead systems are implanted using either transvenous or transthoracic techniques. All rights reserved. Based on the country you select, you can choose the device and lead combination (if applicable) to get scan parameters.